COMELINK IDM INTELLIGENT MICRO MODULE DATA CENTER SOLUTION CABINET SYSTEM INTELLIGENT MICRO-MODULE DATA CENTER

COMELINK IDM INTELLIGENT

  • Detail

Modular integration,Standardized integration of power distribution system, refrigeration system, cabinet system and other subsystems, easy and convenient on-site installation.

Product Introduction:

Modular data center is to make the power distribution system, refrigeration system, dynamic environment monitoring system, fire protection system, security system and cabinet cold aisle system into an intelligent platform, which further improves the safety, reliability, and health of equipment, and is more green and energy-saving.
Modular infrastructure can meet the requirements of customers' special needs and usage, meet the requirements of prefabricated production of all modular internal infrastructure and equipment, assemble, and deliver on site quickly, and truly realize the one-stop solution of rapid deployment of IT equipment. It has the characteristics of modular integration, safety, and reliability, saving room floor space and energy, saving time, labor and worry in installation, compatible architecture, quick and flexible deployment, intelligent monitoring, efficient and stable refrigeration, etc. It is a new generation of intelligent micro-module data center products.

 

 Application Scenario:

 

 It is mainly used in small and medium data center scenarios. Its simple design, strong architectural adaptability, and low requirements for computer room floor height and renovation meet the data center deployment requirements of corporate headquarters or large branches, bank headquarters and secondary branches, government, operators, education, medical care, energy, and other industries.

Taxonomy  Specification Description
Overall Characteristics
Single Row  IDM  Size L*2400(2300)*2000/2200,L≤15m
Double Row  IDM Size L*2400(2300)*2000/2200,L≤15m
Installation Method Installation of Elevated Electrostatic Floor (Recommended) or Direct Cement Floor Installation
Wiring Method Up Wiring or Down Wiring
Distribution System  
Listed in the integrated Distribution Cabinet  
Input Voltage 380/400/415Vac,50/60Hz,3Ph+N+PE
Input Mode Single/Dual
Supporting Capacity (kw) 165; 210; 325
Output Circuit
Air Conditioner Power Supply 4~6 Circuits; IT Power Supply Circuit 2 Groups,
Each Group 24~34 Circuits
Lightning Protection Function B+C Lightning Protection
Other 7-Inch Touch Screen, Support Main and Branch Monitoring, Remote Monitoring
Frame Type UPS   
Input Voltage 380/400/415Vac, 50/60Hz, 3Ph+N+PE
Input Power ≥0.99
Output Power 1.0
Rated Capacity (kVA) ≤150
Overall Efficiency >96%
Entered into the Precision Column Head Cabinet  
Input Voltage (Vac) 380/400/415Vac, 50/60Hz, 3Ph+N+PE
Input Current (A) 100~630
Input Method Single/Dual/Multiple for Options
Output Circuit Switching Capacity 1-63A, Maximum Output 144P
Lightning Protection Function Optional B or C Lightning Protection
Other Color LED Touch Screen, Support Main Road, Branch Road Monitoring, Remote Monitoring
Incorporate modular UPS cabinet  
Input Voltage 380/400/415Vac, 50/60Hz, 3Ph+N+PE
input Power ≥0.99
Output Power 1.0
Rated Capacity (kVA) 100~300
Overall Efficiency >96%
Dequeue Module  
Input Voltage 380/400/415Vac, 50/60Hz, 3Ph+N+PE
input Power ≥0.99
Output Power 1.0
Rated Capacity (kVA) 200~1000
Overall Efficiency >96%
Battery  
Battery Type Lead-Acid Battery/Lithium Iron Phosphate Battery
Cooling System  
Intercolumn Precision Air Conditioner  
Wind Cooling Capacity (KW) 25,30,40,50,60
Chilled Water Type Cooling Capacity (KW) 25,30,40,50,65
Dimensions (W*D*H) mm 600*1100/1200*2000
Room Level Precision Air Conditioning  
Wind Cooling Capacity (KW) 25~100
Chilled Water Type Cooling Capacity (KW) 30~300
Dimensions (W*D*H) mm X*970*1975(Width optional)
Cabinet System  
Dimensions (W*D*H) mm 600*1100/1200*2000,800*1100/1200*2000
Level of Protection IP20
Standard Configuration Cabinet Bottom Plate; Cabinet Fittings; Wire Binding Board/Cable Slot
Optional Accessories
PDU (GB/IEC for Options); Blind Panel; Fixed/Movable Shelf; L-Shaped Bracket;
Cable Management Frame; Light Strip, etc...
Incorporate Battery Cabinet  
Dimensions (W*D*H) mm 600*1100/1200*2000
Degree of Protection IP20
Monitor System  
Alarm Method
Sound and Light Alarm, E-mail Alarm; Mobile Phone SMS Alarm, Mobile APP,
Telephone Voice Alarm Can be Customized
Access Method Remote Web Access, Local 3D/2D Display
Functional Module
Centralized Management (UPS/Air Conditioning/Power Distribution, etc.),
Access Control System, Video System, Environmental System
 (Including Temperature and Humidi